Plumbing Expert

Welcome to the WEBLOG of Wenning Technical Services Pty Ltd; a company providing specialist plumbing consulting, inspection and investigation services.

Monday, September 25, 2006

PVC pipe and stress fracture

PVC pipes and fittings must be installed with provision for movement and expansion.
This fracture in a PVC sweep junction is within an inaccessible first floor space of a three storey commercial building. We located the defect during a process of litigation.